Description

Perfectly suited for demanding applications, the rugged R6P offers oil-less operation ensuring that the discharge air remains free of contamination.  In addition, these blowers have very few moving parts and no wearing components, which minimize downtime and helps to lessen operating noise levels.

Specifications

Thermal Protection: NO
Operating Voltage: 190-220/380-415; 208-230/460
Regulatory Approval: CSA, CE, UKCA
Power Rating @ 50hz: 5 hp
( 3.73 kW )
Power Rating @ 60hz: 5 hp
( 3.73 kW )
Flow‎ @ 50hz: 250 cfm
( 424.75 m3h )
Flow @ 60hz: 275 cfm
( 467.23 m3h )
Max Pressure: 70 in-h20
( 2370.47 mbar )
Max Pressure @ 50hz: 70 in-h20
( 2370.47 mbar )
Max Pressure @ 60hz: 70 in-h20
( 2370.47 mbar )
Max Vacuum @ 50hz: 70 in-h20
( 2370.47 mbar )
Max Vacuum @ 60hz‎: 70 in-h20
( 2370.47 mbar )
Weight: 176 lbs
( 79.83 kg )
Duty Cycle: 100%
Warranty: 1 Year
Thermal Protection: NO
Operating Voltage: 190-220/380-415; 208-230/460
Regulatory Approval: CSA, CE, UKCA
Power Rating @ 50hz: 5 hp
( 3.73 kW )
Power Rating @ 60hz: 5 hp
( 3.73 kW )
Flow‎ @ 50hz: 250 cfm
( 424.75 m3h )
Flow @ 60hz: 275 cfm
( 467.23 m3h )
Max Pressure: 70 in-h20
( 2370.47 mbar )
Max Pressure @ 50hz: 70 in-h20
( 2370.47 mbar )
Max Pressure @ 60hz: 70 in-h20
( 2370.47 mbar )
Max Vacuum @ 50hz: 70 in-h20
( 2370.47 mbar )
Max Vacuum @ 60hz‎: 70 in-h20
( 2370.47 mbar )
Weight: 176 lbs
( 79.83 kg )
Duty Cycle: 100%
Warranty: 1 Year

Downloads

Catalog
Technical Data Sheet
Operating & Maintenance Manual
Gast Catalog

Series Options

Thermal protection

Thermal over load protection protects motor windings from damage should the blower become stalled during operation. Additionally, thermal over load protection switches automatically reset when single-phase motor windings cool to a safe level of operation. 

UL and CSA certified TEFC motor

UL and CSA certified TEFC motors with permanently sealed ball bearings offer increased protection against weather, dirt, and moisture. Permanently sealed ball bearings incorporate polyurea grease, which extends bearing life and offers superior resistance to washout, rust, and corrosion.

Aluminum impeller

Corrosion resistant aluminum impeller promotes extended life. 

Cast iron blower housing and cover

Cast iron blower housing and cover make for a rugged construction.

Pilot duty overload protection

Motors are equipped with pilot duty thermal overload protection that when properly wired to a motor starter limits the motor winding temperature rise.

Variable frequency drive (3 phase motors)

Models with 3 phase motors can be operated with a variable frequency drive for precise speed and flow control.

Explosion Proof

Explosion proof models (R6P155Q-50, R6P355R-50) have motors classified as Explosion Proof Division 1 and 2, which allows blower to be used in Group D explosive atmospheres.  Additionally, these models have sealed air streams to prevent leakage of potentially hazardous gases from unit.